CF TYPE PHYSICAL FOAMED COAXIAL CABLES
FEATURES:
1.  Application: Physical foamed coaxial cables are applied to CATV networks as trunk cable, distribution cable and drop cable, 
     which meet the transmission requirement of broadband, high speed and low loss.
2.  Standards: Q/ST 2-2003 (performance excels GY/T135-1998)
3.   Category &Transmission characteristics: 75Ω,1000MHz.
4.   The braided shield, jacket, flooding compound or steel messenger can be added according to the customers' requirements. 
5.   Cut to order length and customised packaging solutions available.
SPECIFICATIONS
TYPE 5CFB 6CFB 7CFB 7CFBDS 9CFB 9CFBDS 12CFB 12CFBDS
(double jackets) (double jackets) (double jackets)
PHYSICAL DIMENSIONS
CENTER CONDUCTOR  DIAMETERmm 1.00 1.30 1.65 1.65 2.15 2.15 2.77 2.77
MATERIAL COPPER
 DIELECTRIC  DIAMETERmm 4.70 5.80 7.10 7.10 8.90 8.90 11.70 11.70
MATERIAL FOAMED-PE
OUTER  CONDUCTOR AL  FOIL  AL/PET AL/PET AL/PET AL/PET AL/PET/AL AL/PET/AL AL/PET/AL AL/PET/AL
BRAID SIZE 16x4xφ0.12 or 16x3xφ0.12 16x4xφ0.12 16x4xφ0.12 16x4xφ0.12 16x5xφ0.12 16x5xφ0.12 24x4xφ0.12 24x4xφ0.12
MATERIAL TINNED COPPER OR Al-Mg
JACKET DIAMETER(mm)  6.95 8.05 9.50 11.40 11.50 13.50 14.50 16.70
MATERIAL PVC   or   PE
ADHESION FORCE( Sample of 150mm Length) 20N
ELECTRICAL CHARACTERISTICS
CHARACTERISTIC IMPEDANCE (Ω) 75±3 75±2.5 75±2
RETURN LOSS≥dB VHF 20
UHF 18
ATTENUATION (20℃,dB/100m)
5MHz 2.20 1.70 1.50 1.50 1.20 1.20 0.70 0.70
50MHz 4.80 3.90 3.20 3.20 2.40 2.40 1.90 1.90
200MHz 9.00 7.70 5.90 5.90 4.60 4.60 3.80 3.80
550MHz 15.60 13.40 10.40 10.40 8.10 8.10 6.20 6.20
750MHz 18.30 15.80 12.40 12.40 9.50 9.50 7.40 7.40
800MHz 19.00 16.30 12.80 12.80 9.90 9.90 7.70 7.70
1000MHz 22.00 18.20 14.40 14.40 11.30 11.30 8.80 8.80
PACKAGING   INFORMATION
PACKAGE TYPE CARTON PACKAGE CARTON/REEL PACKAGE REEL PACKAGE
LENGTH 2x200m/Coil 2x200m/Coil 1x250m/Coil 1x250m/Coil 350m/Coil 350m/Reel 360m/Reel 360m/Reel
4x100m/Coil 1x300m/Coil 500m/Reel 500m/Reel 500m/Reel 500m/Reel
CARTON DIMENSION(LengthxWidthxHeight) OR REEL DIMENSION   (DxdxL)cm 39x39x20.5 46x46x20.5 44x44x20 57x57x25 57x57x25 φ65xφ28x39 φ60xφ28x39 φ65xφ28x39
63x32x20.5 50x50x20 φ60xφ28x39 φ70xφ28x39 φ70xφ28x39 φ70xφ28x55
NOTE: 1. Al---Aluminum foil  PET----Mylar
 2.  Please use PE jacket outdoors and PVC jacket indoors. 
 3.  Please use double jacket or add flooding compound under the ground (the flooding compound can be filled in the jacket).